Finding:
Unsafe stacking of heat sinks in second floor lab
Finding Category:
-- Select Finding Category --
Compressed Gas Cylinders
Control of Hazardous Energy (Lockout Tagout)
Electrical Safety
Emergency Egress
Emergency Planning
Ergonomics
Fall Protection
Fire Protection
General Work Environment and Housekeeping
Hand and Portable Powered Tools and Equipment
Hazard Communications and Chemicals
Heat-Related Illness Prevention
Infection Control
Machinery and Machine Guarding
Material Handling
Material Storage
Noise Exposure
Overhead Cranes
Personal Protective Equipment
Portable Ladders
Powered Industrial Trucks
Record Keeping
Respiratory Protection
Robots
Safety and Health Policies
Security
Stairs and Stairways
Walkways
Welding and Soldering
Other
Criticality:
-- Select Criticality --
Critical
High
Medium
Low
Proposed Action:
Assigned To:
Assigned to Email:
Containment Due Date:
Containment Action Taken:
Unsafe stacked cores restacked and associates trained on proper stacking
Corrective Action Due:
Updates:
Core repair activities in BG-W are being moved to the mezzanine in BG-R. The additional space in BG-R and the on-site supervision will ensure unsafe stacking does not recur. Move should be complete by the end of November 2024
Corrective Action Taken:
Will evaluate effectiveness of corrective action after move is complete. 2/19/25 - Verified through audit that the materials are properly stored and no stacking occurs
Completion Date:
Corrective Action Pictures (Max 5 MB each, up to 5 images):
Control Method:
-- Select Control Method --
Eliminated
Substituted
Engineered
Administrative
PPE
No New Control
Status: