Update Audit Finding
Finding ID:
104
Finding Location:
Finding:
Method of loading enclosures in Keisling creates poor postures that present ergonomic hazards
Finding Category:
-- Select Finding Category --
Compressed Gas Cylinders
Control of Hazardous Energy (Lockout Tagout)
Electrical Safety
Emergency Egress
Emergency Planning
Ergonomics
Fall Protection
Fire Protection
General Work Environment and Housekeeping
Hand and Portable Powered Tools and Equipment
Hazard Communications and Chemicals
Heat-Related Illness Prevention
Infection Control
Machinery and Machine Guarding
Material Handling
Material Storage
Noise Exposure
Overhead Cranes
Personal Protective Equipment
Portable Ladders
Powered Industrial Trucks
Record Keeping
Respiratory Protection
Robots
Safety and Health Policies
Security
Stairs and Stairways
Walkways
Welding and Soldering
Other
Criticality:
-- Select Criticality --
Critical
High
Medium
Low
Proposed Action:
4/28/25 - this is an open T-card. Dan K. waiting to observe instance. 5/29/25 - lift has been observed, working on a solution (GL) 6/24/2025 Awaiting lift mechanism to complete the process 7/8/2025 Fixture came in and need a unit or similar one to confirm the process.
Assigned To:
Assigned to Email:
Containment Due Date:
Containment Action Taken:
Corrective Action Due:
Updates:
A quote for a lifting device has been requested. Awaiting the quote. There is a plan to build a sequence instruction as how to cut the enclosure safely with minimal movement and it will be fully implemented when the device is in house. Conditional sequence will be added by 6/6/2025. 6/10/2025 Conditional Sequencing instruction has been added 7/1/2025 - Jim to follow up 7/28/2025 - due to production schedule, delayed but planning to complete this week. Need to complete work instruction. 7/29/2025 Work Instruction submitted to David Thurwanger for approval. 8/25/2025 - work instruction approved, can close out.
Corrective Action Taken:
Completion Date:
Corrective Action Pictures (Max 5 MB each, up to 5 images):
Control Method:
-- Select Control Method --
Eliminated
Substituted
Engineered
Administrative
PPE
No New Control
Status:
Not Assigned
Open
Ready for Review
Update Record
Finding Images: