Task 1: Site Arrival & LOTO Verification
Meet with customer representative and discuss the customer representative's responsibilities. Review the site for hazards. Evaluate the environment. Verify the customer has completed lockout to the drive with a group clasp. Yaskawa engineer adds their lock to the group clasp.
| Energy / Category |
Hazard Description |
Risk Level |
Mandatory Control Measures |
|
Other
|
Environmental hazards to be assessed on site. |
Low (Score: 10) |
Customer to present environmental and local hazards with controls. Yaskawa engineer to assess if customer controls are sufficient (If customer control is higher than Yaskawa requirements, associate shall follow customer controls. If Yaskawa controls are greater than customer, the associate shall follow Yaskawa controls).
Walk around work site to identify hazards and determine proper controls. |
Task 2: Verification of Absence of Voltage
1. Assume an energized state until absence of voltage has been verified.
2. Visually verify the digital operator is not operating. Listen to ensure the drive is not operating.
3. Wearing the full PPE required by NFPA study or tables, open the door to the MV drive.
4. Verify operation the digital multiple meter or voltage meter on a known power source
5. Verify absence of voltage to the drive
6. Close and secure MV Drive door.
7. It is now safe to remove PPE
| Energy / Category |
Hazard Description |
Risk Level |
Mandatory Control Measures |
|
Electric Shock or Arc Flash
|
Electric shock or arc flash |
High (Score: 40) |
Door interlocks prevent doors to be opened if medium voltage is present.
Follow PPE requirements on NFPA label, or NFPA 70E tables if incident energy study has not yet been performed. |
Task 3: Wiring Inspection
Inspect all customer supplied wiring to ensure correct termination locations, torque, and clearance. Verify ground bus continuity. Check CT/PT for polarity.
| Energy / Category |
Hazard Description |
Risk Level |
Mandatory Control Measures |
|
Struck-by, Struck-against
|
Working in tight area increases risk of striking a body part against a fixed object |
Low (Score: 6) |
Inspect the work area and plan movements |
Task 4: Removing LOTO and Power Up
1. Ensure no tools are left inside the unit
2. Close and latch all doors securely
3. Coordinate with the customer to remove locks and apply power
| Energy / Category |
Hazard Description |
Risk Level |
Mandatory Control Measures |
|
Electric Shock or Arc Flash
|
Arc Flash during re-energization |
Moderate (Score: 30) |
Power turned on at upstream device following left hand rule. |
Task 5: Parameter Entry
Enter parameters via keypad; verify motor rotation at low speed
| Energy / Category |
Hazard Description |
Risk Level |
Mandatory Control Measures |
|
Other
|
Internal component failure, Unexpected motor rotation |
Low (Score: 8) |
Slow start-up |