Job Hazard Analysis (JHA) #27

JHA Header Information

Identified Hazards & Required Controls (Most Critical First)[cite: 7]
Task 1: Site Arrival & LOTO Verification

Meet with customer representative and discuss the customer representative's responsibilities. Review the site for hazards. Evaluate the environment. Verify the customer has completed lockout to the drive with a group clasp. Yaskawa engineer adds their lock to the group clasp.

Energy / Category Hazard Description Risk Level Mandatory Control Measures
Other Environmental hazards to be assessed on site. Low (Score: 10) Customer to present environmental and local hazards with controls. Yaskawa engineer to assess if customer controls are sufficient (If customer control is higher than Yaskawa requirements, associate shall follow customer controls. If Yaskawa controls are greater than customer, the associate shall follow Yaskawa controls).

Walk around work site to identify hazards and determine proper controls.
Task 2: Verification of Absence of Voltage

1. Assume an energized state until absence of voltage has been verified.
2. Visually verify the digital operator is not operating. Listen to ensure the drive is not operating.
3. Wearing the full PPE required by NFPA study or tables, open the door to the MV drive.
4. Verify operation the digital multiple meter or voltage meter on a known power source
5. Verify absence of voltage to the drive
6. Close and secure MV Drive door.
7. It is now safe to remove PPE

Energy / Category Hazard Description Risk Level Mandatory Control Measures
Electric Shock or Arc Flash Electric shock or arc flash High (Score: 40) Door interlocks prevent doors to be opened if medium voltage is present.

Follow PPE requirements on NFPA label, or NFPA 70E tables if incident energy study has not yet been performed.
Task 3: Wiring Inspection

Inspect all customer supplied wiring to ensure correct termination locations, torque, and clearance. Verify ground bus continuity. Check CT/PT for polarity.

Energy / Category Hazard Description Risk Level Mandatory Control Measures
Struck-by, Struck-against Working in tight area increases risk of striking a body part against a fixed object Low (Score: 6) Inspect the work area and plan movements
Task 4: Removing LOTO and Power Up

1. Ensure no tools are left inside the unit
2. Close and latch all doors securely
3. Coordinate with the customer to remove locks and apply power

Energy / Category Hazard Description Risk Level Mandatory Control Measures
Electric Shock or Arc Flash Arc Flash during re-energization Moderate (Score: 30) Power turned on at upstream device following left hand rule.
Task 5: Parameter Entry

Enter parameters via keypad; verify motor rotation at low speed

Energy / Category Hazard Description Risk Level Mandatory Control Measures
Other Internal component failure, Unexpected motor rotation Low (Score: 8) Slow start-up

Station Details

Station Controls

Signs Barriers Other Controls

Environmental Factors

Workstation Images

Required Competencies

Tools Used

Chemicals Used

Job Tasks and Hazards

Required PPE

Eye Protection
Safety Glasses w/ Shields
Vented Goggles
Non-Vented Goggles
Welding Helmet/Shield
Laser Protection
UV Protection
Face Shield
Head Protection
Type 2 Class G
Bump Cap
Hearing Protection
Hearing Protection
Respiratory Protection
Filtered Face Mask
Half-Face P100
Organic Vapor
Foot Protection
Toe Protection
Electrical Hazard
ESD
Metatarsal
Puncture Resistant
Chemical Resistant
Electrical Protection
Class 0 Gloves
Class 1 Gloves
Class 2 Gloves
CAT 1 Arc
CAT 2 Arc
CAT 3 Arc
CAT 4 Arc
Natural Fiber
Arc-Rated Clothes

Ergonomic Assessment

Wrists
PosturesForceDurationFrequency
Left Wrist
Right Wrist
Ergonomic Stressors